Equipment Calibration Page
You can capture the calibration of equipment specified on the Variable Data page. Calibrations allow you to determine whether equipment is recording the correct value, or if it may need to be adjusted.
Record a Calibration
-
Use CALIBRATION DATE to enter the date of your calibration.
- The date is pre-populated with the device's current date.
-
Tap CALIBRATION DATE to display the calendar dialogue to change the date of the calibration.
- Tap the appropriate date to select it.
-
Use NEXT CALIBRATION DATE to enter the next scheduled calibration date for the
- The date is pre-populated with the day after the device's current date.
-
Tap NEXT CALIBRATION DATE to display the calendar dialogue allowing you to select the date the EQUIPMENT is to be re-calibrated.
- Tap the appropriate date to select it.
-
VARIABLES, SITE VALUE, VALUE and % DIFF allow for capturing differences in Variable values recorded on site (SITE VALUE) versus expected values (CAL. VALUE), and displays the difference between the two as a percentage (% DIFF).
-
Underneath SITE VALUE is displayed the list of Variables available (as determined by the DataSight MDE Template selected on the Start page) for recording values against.
-
The VARIABLE NAME field is for entering the measurement as recorded by the equipment at site.
-
VALUE is for entering the measurement as recorded by the secondary equipment, used to undertake the calibration.
-
% DIFFERENCE will be automatically calculated by DSApp using the formula:
-
% DIFFERENCE equals (( VALUE minus SITE VALUE) divided by CAL. VALUE) multiplied by 100.
- Use this value to determine whether the difference in measured values are acceptable, or if the equipment requires adjustment.
-
Tap NEXT to proceed to the next page as determined by your DSApp Configuration.
-
If the background of the NEXT button turns red, then one of the above items have not been entered correctly. Please review your entries and try again.
Related Articles
Equipment Calibration
The Equipment Calibration window can be used to add calibration details required for the equipment, such as calibration dates, together with comments. Open the Calibration window Select the Edit Calibration button in the equipment row against which ...
Variable Data Page
You can use the VARIABLE DATA page to enter data in a similar fashion to Manual Data Entry (MDE) in DataSight. LEVEL 3 displays the Level 3 that was selected on the Safety page. Collect Data The DATE and TIME fields are used to set the datetime ...
Equipment
Add a Piece of Equipment Select the Equipment tab in the Main Panel. To add equipment, click New in the Quick Access Toolbar and a new row at the bottom of the Equipment table will be added. Click the Active checkbox to identify whether the Equipment ...
Video: Set Person & Equipment
This video tutorial demonstrates how to set person and equipment in DataSight.
Sampling Page
The Sampling page is used to record sample codes as required. Sample codes are exported to the DATASIGHT VARIABLE specified in the selected DSApp Configuration, and is referred to below as the "Sample Code". If recording sample codes is required, tap ...